B14F1-18 Bank 'A' motor #3 Output - Circuit current below threshold: Action
- 18-way and 12-way specification seating: Refer to the electrical circuit diagrams and check the seat forward/rearward motor circuit for short circuit to ground, short circuit to power. Repair circuit as required. Clear DTC and retest
- 18-way and 12-way specification seating: If fault persists, install a new seat forward/rearward motor
- 8-way specification seating: Refer to the electrical circuit diagrams and check the seat height motor circuit for short circuit to ground, short circuit to power. Repair circuit as required. Clear DTC and retest
- 8-way specification seating: If fault persists, install a new seat height motor