DTC B13CB-11: Roof Blind Module - Circuit short to ground: Action
- Refer to the applicable system wiring diagram(s) and check the roof opening panel control module circuit for short circuit to ground. Repair wiring harness as required, clear the DTC and retest the system
- If no wiring faults are present, check and install new roof opening panel control module motor as required. Clear DTC and retest