DTC B10F9-11: Accessory Socket 'B' Relay - Circuit short to ground: Action
- Refer to the applicable SYSTEM WIRING DIAGRAMS and check the cigar lighter relay circuit for short circuit to ground. Repair circuit as required, clear DTC and retest
- If fault persists, check and install a new cigar lighter relay
- Using the manufacturer approved diagnostic system, clear the DTCs and retest. If the fault persists, install a new central junction box