DTC B14EF-19: Bank 'A' motor #1 Output - Circuit current above threshold: Action
NOTE:
This DTC does not apply to 8-way specification seating
- Refer to the appropriate system wiring diagrams and check the seat height motor circuit for short circuit to ground, short circuit to power. Repair circuit as required. Clear the DTCs and retest
- If fault persists, install a new seat height motor