Section 55 (Diagnostic Trouble Code (DTC) Index DTC: Gateway Module (GWM) -- F-Type/X152)
WARNING: This page is about a different car, the 2018 Jaguar F-Type, 2017 Jaguar F-Type, 2016 Jaguar F-Type, 2015 Jaguar F-Type, and 2014 Jaguar F-Type. However, it is still accessible from the selected car via links, so may be relevant.
- Diagnostic Trouble Code (DTC) Index DTC: Gateway Module (GWM)
- Description And Operation
- Gateway Module (GWM)
- Notes
- B11DB-49: Battery Monitoring Module A - Internal electronic failure
- B11DB-87: Battery Monitoring Module A - Missing message
- B12CD-16: Voltage Quality Module - Circuit voltage below threshold
- B12CD-19: Voltage Quality Module - Circuit current above threshold
- B12CD-87: Voltage Quality Module - Missing message
- B12CD-92: Voltage Quality Module - Performance or incorrect operation
- B12CD-96: Voltage Quality Module - Component internal failure
- B13C5-92: Secondary Battery - Performance or incorrect operation
- B1404-13: Charging System - Circuit open
- B1412-09: Quiescent Relay Box - Component failures
- B1412-87: Quiescent Relay Box - Missing message
- B1412-96: Quiescent Relay Box - Component internal failure
- B1479-08: Power Supply Distribution Box - Bus signal/message failures
- B1479-14: Power Supply Distribution Box - Circuit short to ground or open
- B1479-72: Power Supply Distribution Box - Actuator stuck open
- B1479-73: Power Supply Distribution Box - Actuator stuck closed
- B1479-96: Power Supply Distribution Box - Component internal failure
- B1479-98: Power Supply Distribution Box - Component or system over temperature
- P0620-00: Generator Control Circuit - No sub type information
- P065B-16: Generator Control Circuit Range/Performance - Circuit voltage below threshold
- P065B-17: Generator Control Circuit Range/Performance - Circuit voltage above threshold
- P065C-01: Generator Mechanical Performance - General electrical failure
- P0A0F-71: Engine Failed To Start - Actuator stuck
- P0A1A-87: Generator Control Module - Missing message
- P0A3B-68: Generator Over Temperature - Event information
- U0028-81: Vehicle Communication Bus A - Invalid serial data received
- U0028-87: Vehicle Communication Bus A - Missing message
- U0028-88: Vehicle Communication Bus A - Bus off
- U0037-81: Vehicle Communication Bus B - Invalid serial data received
- U0037-87: Vehicle Communication Bus B - Missing message
- U0037-88: Vehicle Communication Bus B - Bus off
- U0046-87: Vehicle Communication Bus C - Missing message
- U0046-88: Vehicle Communication Bus C - Bus off
- U0055-87: Vehicle Communication Bus D - Missing message
- U0055-88: Vehicle Communication Bus D - Bus off
- U0064-87: Vehicle Communication Bus E - Missing message
- U0064-88: Vehicle Communication Bus E - Bus off
- U0300-46: Internal Control Module Software Incompatibility - Calibration/parameter memory failure
- U1A14-00: CAN Initialisation Failure - No sub type information
- U2100-00: Initial Configuration Not Complete - No sub type information
- U2300-41: Central Configuration - General checksum failure
- U2300-51: Central Configuration - Not programmed
- U2300-54: Central Configuration - Missing calibration
- U2300-56: Central Configuration - Invalid/incomplete configuration
- U2300-57: Central Configuration - Invalid/incomplete software component
- U2300-64: Central Configuration - Signal plausibility failure
- U3000-04: Control Module - System internal failures
- Gateway Module (GWM)
- Description And Operation