Discharging A/C System
NOTE:
Recent findings by the EPA indicate that refrigerant is harmful to the Earth's protective Ozone layer. When discharging refrigerant, avoid allowing refrigerant to enter the atmosphere. Refrigerant recovery/recycle system should be used whenever possible instead of discharging system. Many states now require by law the use of recovery/recycle systems. Check local laws before proceeding.
- Close both valves on manifold gauge set. Connect manifold gauge set to the high and low side service valves. See SERVICE VALVE LOCATIONS under SYSTEM SERVICE VALVES in this article.
- Fully open both valves on manifold gauge set. Connect a discharge hose to center connector on manifold gauge set. Place discharge hose in shop exhaust hose or in well ventilated area.
- Open service valves slightly to the mid-position. DO NOT discharge refrigerant rapidly, as refrigerant oil will be lost from system. Once discharged, close valves on manifold gauge set to prevent entry of moisture into system.