Possible Causes
| Possible Causes |
|---|
| (K961) IAC RETURN CIRCUIT SHORTED TO BATTERY VOLTAGE |
| (K61) IAC CONTROL CIRCUIT SHORTED TO BATTERY VOLTAGE |
| (K61) IAC CONTROL CIRCUIT SHORTED TO THE (K961) IAC RETURN CIRCUIT |
| IAC MOTOR |
| PCM |
Always perform the Pre-Diagnostic Troubleshooting procedure before proceeding. Refer to PRE-DIAGNOSTIC TROUBLESHOOTING PROCEDURE .