Home >> Jeep >> 2007 >> Commander Overland, 4WD >> Repair and Diagnosis (Single Page) >> Accessories & Equipment >> Communication Devices >> Electronic Control Modules (Service Information) >> Electronic Control Modules >> Module-Final Drive Control >> Operation >> Final Drive Control Module >> Transfer Case Range Select Switch Input (Neutral & 4HI/4LO Select Switch)
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Transfer Case Range Select Switch Input (Neutral & 4HI/4LO Select Switch)

The FDCM will support circuitry which interfaces to the system's Transfer Case Range Select Switch, including a Transfer Case Range Select Switch voltage supply and a Transfer Case Range Select Switch input. The purpose of this circuitry is to determine the mode currently being requested by the operator via the resistance ladder network in the shifter assembly, where the Transfer Case Range Select Switch is packaged.

The NEUTRAL Select Switch Input will provide the operator with the ability to place the Transfer Case in Neutral. The 4HI/ 4LO Select Switch Input will provide the operator with the ability to place the transfer case in 4HI or 4LO. The NEUTRAL Select Switch is a momentary contact switch and the 4HI/4LO Select Switch is a 2-position toggle or a momentary contact switch and both these switches are provided through a resistor network for diagnostic purposes. The input will have an internal 1.0K +/- 1% pull-down resistor to ground.

As the selected position in the 4HI/4LO Switch varies and/or the NEUTRAL Switch is depressed or not, the resistance between the module's Transfer Case Range Select Switches voltage supply and Transfer Case Range Select Switches input will vary. Hardware, software, and calibrations within the FDCM will be provided that interpret the external resistance between the module's Transfer Case Range Select Switches voltage supply and Transfer Case Range Select Switches inputs as given in the table below:

RESISTANCE RANGE

STEP RESISTANCE RANGE REQUIRED INTERPRETATION
A 63<111<140.4 Fault Condition (short)
B 309.7<337<364.39 NEUTRAL from 4LO (1)
C 380.93< 414<448.20 NEUTRAL from 4HI (1)
D 910.87< 990< 1071.72 4LO
E 2024.17< 2200< 2381.61 4HI
F Greater Than 8661.5<9000<9343 Fault condition (open)
NOTE: There is no requirement for the FDCM to distinguish between a neutral request from the 4LO or the 4HI position. Resistances in these ranges will be represented as a Neutral Switch Activation.