Sensor, Intelligent Battery (IBS): Installation: Installation
NOTE:
Connecting the negative battery cable to the Intelligent Battery Sensor (IBS) must be done before installing on the battery post.
- Install the negative battery cable to the IBS (2).
- Install the IBS negative battery cable retainer (1).
Tighten to 16 N.m (12 Ft. Lbs).
- Install the IBS (5) on the negative post of the battery.
- Tighten the captive nut (4) to 8 N.m (72 In. Lbs.).
- Connect the IBS electrical connector (3) to the IBS (5).