  1. Position the generator to the vehicle for installation.
    GC0161977Courtesy of CHRYSLER GROUP, LLC
  2. Install the upper generator bolt.
    GC0161973Courtesy of CHRYSLER GROUP, LLC
  3. Install the lower generator bolt. You may need to reposition the generator to get the bolt hole in the intermediate bearing shaft support and the generator to line up properly.
  4. Connect all connectors to the generator.
    GC0161818Courtesy of CHRYSLER GROUP, LLC
  5. Position the exhaust back into proper position and install bolts to the flange to secure.
    GC0162128Courtesy of CHRYSLER GROUP, LLC
  6. Install the Diesel Exhaust Fluid (DEF) injector. Refer to INJECTOR, DIESEL EXHAUST FLUID, INSTALLATION .
  7. Install the serpentine belt. Refer to BELT, SERPENTINE, INSTALLATION - 3.0L DIESEL .
  8. Connect the negative battery cables.