Set Condition
- The PCM will detect a fault in the feedback voltage with the EGR Valve closed if:
- the feedback voltage is below 0.3 volts.
- the feedback voltage is above 0.8 volts.
- the feedback voltage is more than 0.12 volts different from the last saved value.