When Monitored
This diagnostic runs when the following conditions are met:
- With the ignition on.
- Every time the EGR Valve is in the closed position the zero position voltage is checked to see if it is within the expected range.
- If the EGR Valve is within the expected range, that voltage value is saved as the new zero position voltage.