LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Kia >> 2000 >> Spectra GS L4-1.8L >> Repair and Diagnosis >> Heating and Air Conditioning >> Ambient Temperature Sensor / Switch HVAC >> Testing and Inspection
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Ambient Temperature Sensor / Switch HVAC: Testing and Inspection

A/C Thermostat
1. Remove glove box.
2. Run engine at idle.
3. Turn A/C switch OFF and set blower switch to highest position to operate blower fan for a few minutes.
4. After a few minutes, turn blower switch OFF and stop engine.
5. Disconnect A/C thermostat connector and connect test light.







6. Apply 12 V to terminal 4 (BLU/YEL) of A/C thermostat and ground terminal 1 (BLU/WHT) and verify that test light illuminates as follows.
7. If not as specified, replace A/C thermostat.

NOTE:
a. The A/C thermostat contacts will be open if evaporator temperature is below 34.7 ± 0.9° F (1.5 ± 0.5° C).
b. Test light will be illuminated.