System Inspection: Notes
- Start the engine and raise the engine speed to 2, 500~3, 000 RPM.
- Turn ON all electrical loads by turning on the headlamps, and by turning on the high blower motor, etc.
- Monitor the battery(ignition) voltage parameter on the GDS data list.VOLTAGE SPECIFICATION
Ambient temperature °C(°F) Reference Voltage(V) -20(-4) Approx. 14.2~15.4 20(68) Approx. 14.0~15.0 60(140) Approx. 13.7~14.9 80(176) Approx. 13.5~14.7 - Is the battery voltage within the specification?
YES
- Go to next step as below.
NO
- Possibility of charging system malfunction. Repair or replace alternator and battery. Refer to Charging System group in Service Information. And then go to "VERIFICATION OF VEHICLE REPAIR " procedure.