Battery Refresh Logic (Partial SOC) Release Procedure
If "ISG Inhibition Condition Due to Urgent Charging Battery Logic(Low SOC)" is ON in the current data as below, battery refresh logic release procedure should be performed.
There are 2 methods to release the battery refresh logic.
Method 1) Chrge the battery more than 95% SOC.
Method 2) Drive the vehicle until total driving time is more than 2 hours.
- Perform one of two methods.
- Check "ISG Inhibition Condition Due to Urgent Charging Battery Logic(Low SOC)" is OFF using GDS.