RPAS Alarm System
WARNING: This page is about a different car, the 2017 Kia Soul EV. However, it is still accessible from the selected car via links, so may be relevant.
When the RPAS sensor detects the object, warning is given from an audible alarm device such as buzzer. RPAS sensor sends data to BCM via LIN communication and BCM gives an audible warning for each RPAS SENSOR by priority. It then performs a role of gateway only when it sends visible alarm to display device such as Cluster.
- When information is received from RL/RR sensors, the BCM directly handles information of each sensor according to display and buzzer output functions. For the buzzer output of CL/CR sensors, the BCM handles the integrated information of both sensors by priority. However, when displaying the failure information, the BCM sends information of each sensor to the cluster.