Control Circuit Inspection
■ Open & Short Circuit Inspection
- IG "OFF" and disconnect FRP connector.
- IG "ON".
- Measure voltage between Pin No. 2 (High) terminal of FRP harness connector and chassis ground.
- Measure voltage between Pin No. 1 (Low) terminal of FRP harness connector and chassis ground.
Specification:
FPR High Terminal Approx. 2.2V
FPR Low Terminal Approx. 0V
- Is the measured voltage within specification?
YES
- Go to "COMPONENT INSPECTION " procedure.
NO
- Repair or replace as necessary and then, go to "VERIFICATION OF VEHICLE REPAIR " procedure.