Connector [A]

Pin No. Signal Condition Type Level
29 Manual mode up switch Up ON Input 0V/Battery voltage level
Other 9V < Battery voltage level < 16V
44 Inhibitor switch signal "S1" ON Input 9V < Battery voltage level < 16V
OFF 0V/Battery voltage level
45 Inhibitor switch signal "S2" ON Input 9V < Battery voltage level < 16V
OFF 0V/Battery voltage level
46 Inhibitor switch signal "S3" ON Input 9V < Battery voltage level < 16V
OFF 0V/Battery voltage level
47 Inhibitor switch signal "S4" ON Input 9V < Battery voltage level < 16V
OFF 0V/Battery voltage level
54 Manual mode down switch Down ON Input 0V/Battery voltage level
Other 9V < Battery voltage level < 16V
79 Manual mode select switch Sport mode Input 0V/Battery voltage level
Other 9V < Battery voltage level < 16V
85 Rear lamp relay R ON Output 0V/Battery voltage level
Other 9V < Battery voltage level < 16V
86 P/N relay P-R change Output Min. Operation voltage:
Battery voltage ≥ 6.0V
Max. Operation voltage:
Battery voltage ≤ 16.0V
P/N range position