Repair Procedures: Replacement
WARNING: This page is about a different variant/trim than selected.
- Remove the air cleaner assembly.
(Refer to "AIR CLEANER .")
- Remove the battery and battery tray.
(Refer to "BATTERY .")
- Disconnect the back up lamp switch connector (A).
- Remove the back up lamp switch (A).
- Replace a new one and install the back up lamp switch.
Tightening torque:
39.2 ~ 58.8 N.m (4.0 ~ 6.0 kgf.m, 28.9 ~ 43.4 lb-ft)