Home >> Kia >> 2017 >> Optima Plug-In Hybrid EX >> Repair and Diagnosis >> Engine Performance >> System >> Engine Control System Diagnosis (3 Of 3) (PHEV) >> DTC P24BA-00: EVAP System Leak Detection Pump Pressure Sensor Circuit Low >> Component Inspection >> Purge Control Solenoid Valve Coil Resistance Inspection >> Notes
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Purge Control Solenoid Valve Coil Resistance Inspection: Notes

  1. Ignition "OFF".
  2. Disconnect Battery (-) terminal.
  3. Refer to PURGE CONTROL SOLENOID VALVE (PCSV) and disconnect Purge Control Solenoid Valve connector.
  4. Measure resistance between Pin No. 1 (Power) terminal and Pin No. 2 (Control) terminal of Purge Control Solenoid Valve component.

    Specification  : Approx. 19.0 to 22.0Ω at 68°F (20°C)

  5. Is the measured value within specification?

    YES 

    • Fault might be intermittent and caused either by poor contact in connectors or wiring harness, or it has been repaired and control module memory is not cleared yet. Thoroughly check terminal of battery, all connectors (and connections) for looseness, bending, corrosion, contamination, deterioration, and/or damage.
    • Repair or replace as necessary and then go to "Verification of Vehicle Repair " procedure.

    NO 

    CAUTION:
    • Install the component with the specified torques.
    • Note that internal damage may occur when the component is dropped or mistreated.
    • Keep foreign materials out of the valve.