Ground Circuit Inspection
- Ignition "OFF"
- Disconnect Battery (-) terminal.
- Refer to ELECTRIC WATER PUMP (EWP) and disconnect EEWP connector.
- Measure resistance between Pin No. 6 (Ground) terminal of EEWP harness connector and chassis ground.
Specification : Approx. below 1Ω
- Is measured value within specification?
YES
- Go to "Open in CAN Communication Line Inspection " procedure.
NO
- Repair open or short in ground circuit, and then go to "Verification of Vehicle Repair " procedure.