Repair Procedures: Installation
- Install in the reverse order of removal.
NOTE:
- Be careful not to damage other hose when tightening the clamp. tightening the clamp.
- Install the clamp in the specified direction to prevent interference with surrounding components.
- Perform the resolver calibration using the GDS.
(Refer to Hybrid Motor Control System - "RESOLVER SENSOR ")
- Refill the hybrid cooling system with coolant and bleed air from the hybrid cooling system using GDS.
(Refer to Hybrid Motor Cooling System - "COOLANT ")