Repair Procedures: Removal
WARNING: This page is about a different variant/trim than selected.
- Remove the coupling assembly.
(Refer to Coupling Assembly - "DIRECT ELECTRO HYDRAULIC ACTUATOR COUPLING ")
- Remove the extension cable (A).
- Remove the pressure sensor (A) with 24 mm socket.NOTE:
- Remove the pressure sensor while maintaining it horizontally to prevent leakage of oil.
Tightening torque:
7.8 - 9.8 N.m (0.8 - 1.0 kgf.m, 5.8 - 7.2 lb-ft)