Component Inspection
| Inspect ECTS | |||||
|---|---|---|---|---|---|
| Inspection Condition | (+) Probe | (-) Probe | Reference | ||
| Connector | Terminal | Connector | Terminal | ||
|
ECTS (component side) | 1 (signal) | ECTS (component side) | 2 (ground) | Table1 |
RESISTANCE OF ENGINE COOLANT TEMPERATURE SENSOR (ECTS)
| Temperature | Resistance (kΩ) | Temperature | Resistance (kΩ) | ||
|---|---|---|---|---|---|
| °C | °F | °C | °F | ||
| -40 | -40 | 48.14 | 60 | 140 | 0.59 |
| -20 | -4 | 14.13 to 16.83 | 80 | 176 | 0.32 |
| 0 | 32 | 5.79 | 100 | 212 | 0.19 |
| 20 | 68 | 2.31 to 2.59 | 110 | 230 | 0.145 to 0.149 |
| 40 | 104 | 1.15 | 120 | 248 | 0.12 |
Good
- Go to "VERIFICATION OF REPAIR " procedure.
No Good
- Carefully re-do this troubleshooting guide steps.
- If no problems were found with the circuits or connectors, replace the ECTS and go to "VERIFICATION OF REPAIR " procedure.