Protection Of Wireless Power Charger System
| Item | Condition | Status |
|---|---|---|
| Protects against low/high voltage | Protects and stops charging under 8.5 V and over 16.5 V | LED OFF (Stops operation) |
| Charges over 9.0 V and under 16.0 V | ||
| Protects against reverse voltage | Protects and stops charging in case of reverse voltage | LED OFF (Stops operation) |
| Protects against overcurrent | Protects and stops charging in case of detecting 4.5 A | Amber LED blinks |
| Protects against overheating | Protects and stops charging in case of detecting 158°F (70°C) by internal temperature sensor of wireless charging module | Amber LED blinks |
| Resumes under 149°F (65°C) | ||
| Foreign matter (Coins, clips, precious metals, etc.) |
Protects and stops charging in case of detecting foreign matter (overheating prevention) | Amber LED blinks |
| Prevents frequency interference | Protects and stops charging by activating SMK in case door or liftgate is open | LED OFF (Stops operation) |
| Resumes in 3.5 seconds after all doors and liftgate are closed and SMK operation is completed | ||
| Alert for contact with mobile phone | In case of smart phone on the charging pad when opening the door after ignition OFF | Displays warning message on the instrument panel (for about 4-5 seconds) |
* Liftgate applies to RV vehicle models.