| DTC Strategy |
Case 1 |
|
- Poor connector connection
- Faulty ITM position sensor circuit
- Faulty ITM position sensor
|
| Case 2 |
|
| Case 3 |
- Plausibility monitoring (high)
|
| Case 4 |
- Plausibility monitoring (low)
|
| Enable Conditions |
Case 1, 2 |
- Ignition "ON"
- No DTC P26A600, P26A700, U063F00
- No faulty ITM sensor
|
| Case 3 |
- Faulty ITM control is higher than 4 stage
|
| Case 4 |
- Faulty ITM control is lower than 4 stage
|
| Threshold Value |
Case 1 |
- Position angle is higher than 265°
|
| Case 2 |
- Position angle is lower than 0°
|
| Case 3 |
- Position angle of ITM is higher than 126°
|
| Case 4 |
- Position angle of ITM is lower than 126°
|
| Diagnostic Time |
Case 1, 2 |
|
| Case 3, 4 |
|
| MIL ON Condition |
|