| B1193-53 |
Crash Event Storage Full and Locked - deactivated |
|
- Clear diagnostic trouble code and re-test
|
| B1A54-01 |
Occupant Belt Tension Sensor - General Electrical Failure |
- General electrical failure
|
- Clear diagnostic trouble code and re-test. If the problem persists, check and install a new safety belt tension sensor as required. Refer to the warranty policy and procedures manual, or determine if any prior approval programme is in operation, prior to the installation of a new module/component
|
| B1A54-02 |
Occupant Belt Tension Sensor - General signal failure |
|
- Refer to the electrical circuit diagrams and check safety belt tension and mat pressure sensor circuits for short to each other
|
| B1A54-11 |
Occupant Belt Tension Sensor - circuit short to ground |
- Safety belt tension sensor voltage reference or signal circuit - short to ground
|
- Refer to the electrical circuit diagrams and check safety belt tension sensor voltage reference and signal circuits for short to ground
|
| B1A54-12 |
Occupant Belt Tension Sensor - circuit short to battery |
- Safety belt tension sensor voltage reference or signal circuit - short to power
|
- Refer to the electrical circuit diagrams and check safety belt tension sensor voltage reference and signal circuits for short to power
|
| B1A54-13 |
Occupant Belt Tension Sensor - circuit open |
- Safety belt tension sensor voltage reference or signal circuit - open circuit
|
- Refer to the electrical circuit diagrams and check safety belt tension sensor voltage reference and signal circuits for open circuit
|
| B1A62-02 |
Pressure Sensor - General signal failure |
|
- Refer to the electrical circuit diagrams and check safety belt tension and mat pressure sensor circuits for short to each other
|
| B1A62-11 |
Pressure Sensor - circuit short to ground |
- Mat pressure sensor voltage reference or signal circuits - short to ground
|
- Refer to the electrical circuit diagrams and check mat pressure sensor voltage reference and signal circuits for short to ground
|
| B1A62-12 |
Pressure Sensor - circuit short to battery |
- Mat pressure sensor voltage reference, ground or signal circuits - short to power
|
- Refer to the electrical circuit diagrams and check mat pressure sensor voltage reference, ground and signal circuits for short to power
|
| B1A62-13 |
Pressure Sensor - circuit open |
- Mat pressure sensor voltage reference or signal circuit - open circuit
|
- Refer to the electrical circuit diagrams and check mat pressure sensor voltage reference and signal circuits for open circuit
|
| B1A62-7B |
Pressure Sensor - low fluid level |
- Low fluid level - bladder damaged
|
- Check and install new bladder as required. Refer to the warranty policy and procedures manual, or determine if any prior approval programme is in operation, prior to the installation of a new module/component
|
| U0001-88 |
High Speed CAN Communication Bus - Bus off |
|
- Refer to the electrical circuit diagrams and check CAN network for short, open circuit. Carry out the CAN network integrity test using the manufacturer approved diagnostic system
|
| U0151-00 |
Lost Communication With Restraints Control Module - no sub type information |
- Restraints control module missing message
|
- Refer to the electrical circuit diagrams and check power and ground supplies to restraints control module. Carry out CAN network integrity test using the manufacturer approved diagnostic system
|
| U0300-00 |
Internal Control Module Software Incompatibility - no sub type information |
- Master car configuration file ID does not correspond
|
- Check correct occupancy seat module is installed for vehicle specification. Check auxiliary junction box for related diagnostic trouble codes and refer to relevant diagnostic trouble code index
|
| U2016-51 |
Control Module Main Software - not programmed |
- Main software not programmed
|
- Check and install a new occupancy seat module as required. Refer to the warranty policy and procedures manual, or determine if any prior approval programme is in operation, prior to the installation of a new module/component
|
| U201A-51 |
Control Module Main Calibration Data - not programmed |
- Main calibration data not programmed
|
- Check and install a new occupancy seat module as required. Refer to the warranty policy and procedures manual, or determine if any prior approval programme is in operation, prior to the installation of a new module/component
|
| U3000-04 |
Control Module - System Internal Failures |
- Occupancy seat module internal electronic failure
|
- Check and install a new occupancy seat module as required. Refer to the warranty policy and procedures manual, or determine if any prior approval programme is in operation, prior to the installation of a new module/component
|
| U3000-54 |
Control Module - missing calibration |
- This diagnostic trouble code is set if a 'calibrate occupancy seat module empty seat offset' routine is requested and fails due to one of the pre-conditions to execute the routine
|
- Check the following criteria have all been achieved: Ignition status set to RUN/START. Verify seat is always empty after power-up before re-zero is requested. The occupancy seat module has gone through the seat assembly plant calibration. No collision event received from the restraints control module during the current ignition cycle. No faults present in the current ignition cycle. The trigger message for calibrate empty seat offset has been received from the diagnostic tool. Occupancy seat module has enough time to begin classification. Temperature is between 6C (42F) and 36C (97F)
|
| U3003-16 |
Battery Voltage - circuit voltage below threshold |
- Circuit voltage below threshold
|
- Check battery is in fully charged and serviceable condition. Check integrity of charging system
|
| U3003-17 |
Battery Voltage - circuit voltage above threshold |
- Circuit voltage above threshold
|
- Check battery is in fully charged and serviceable condition. Check integrity of charging system
|