DTC U3000-01: Control module - General electrical failure: Action
- Check integrity of electrical connectors and pins to the adaptive damping system control module. Refer to the appropriate system wiring diagrams and check the power and ground circuits to the adaptive damping system control module. Check the damper negative circuits for short to ground. Clear the DTC and retest. If the problem persists, renew the adaptive damping system control module