DTC B0022-11: Left Curtain Deployment Control 2 - Circuit short to ground: Action
- Visually inspect the left side air curtain Ak2 connector, the locking plunger should be flush with the housing. If not, push the locking plunger in. Clear the DTCs and retest
- Refer to the appropriate system wiring diagrams and check the left side air curtain circuit for short circuit to ground