DTC C1119-7B: Hydraulic Pressure - Low fluid level: Action
- Check and top up the hydraulic fluid as required
- Check integrity of hydraulic system and rectify any leaks as required. Clear the DTCs and retest
- If the fault persists, install a new filter. Clear the DTCs and retest
- If the fault persists, install a new hydraulic pump. Clear the DTCs and retest
- If the fault persists, check the suction hose for blockage or kinking and rectify or replace as required. Clear the DTCs and retest