Pinpoint Test F: Transfer Case Actuator Temperature Sensor Circuit Tests
- F1: TRANSFER CASE WIRING HARNESS AND ACTUATOR TEMPERATURE SENSOR LOW RESISTANCE
- Set the ignition to off.
- Disconnect the largest wiring harness connector from the transfer case control module.
- Connect an ohm-meter to terminal 5 and terminal 2 of the transfer case control module wiring harness connector.
- Measure the resistance.
Is the measured resistance less than 1 kΩ?
- F2: TRANSFER CASE ACTUATOR TEMPERATURE SENSOR LOW RESISTANCE
- Disconnect the wiring harness connector from the transfer case actuator.
- Connect an ohm-meter to terminal 4 and terminal 7 of the transfer case actuator.
- Measure the resistance.
Is the measured resistance less than 1 kΩ?
- Yes : Resistance too low. Install a new transfer case actuator.
- No : Resistance not too low. Check the transfer case actuator wiring harness for short circuit between the wires. Repair the wiring harness as necessary.
- F3: TRANSFER CASE WIRING HARNESS AND ACTUATOR TEMPERATURE SENSOR HIGH RESISTANCE
- Connect an ohm-meter to terminal 5 and terminal 2 of the transfer case control module wiring harness connector.
- Measure the resistance.
Is the measured resistance greater than 30 kΩ?
- F4: TRANSFER CASE ACTUATOR TEMPERATURE SENSOR HIGH RESISTANCE
- Disconnect the wiring harness connector from the transfer case actuator.
- Connect an ohm-meter to terminal 4 and terminal 7 of the transfer case actuator.
- Measure the resistance.
Is the measured resistance greater than 30 kΩ?
- Yes : Resistance too high. Install a new transfer case actuator.
- No : Resistance not too high. Check the transfer case actuator wiring harness for open circuit, high resistance. Repair the wiring harness as necessary.
- F5: TRANSFER CASE WIRING HARNESS AND ACTUATOR TEMPERATURE SENSOR SHORT CIRCUIT TO GROUND
- Connect an ohm-meter to terminal 5 of the transfer case control module wiring harness connector and ground.
- Measure the resistance.
Is the measured resistance infinitely high (open circuit)?
- Yes : No short circuit to ground. No fault found.
- No : Short circuit to ground. GO to F6.
- F6: TRANSFER CASE ACTUATOR TEMPERATURE SENSOR SHORT CIRCUIT TO GROUND
- Disconnect the wiring harness connector from the transfer case actuator.
- Connect an ohm-meter to terminal 5 of the transfer case control module wiring harness connector and ground.
- Measure the resistance.
Is the measured resistance infinitely high (open circuit)?
- Yes : Short circuit to ground. Install a new transfer case actuator.
- No : No short circuit to ground. Check the transfer case actuator wiring harness for short circuit to ground. Repair the wiring harness as necessary.