Pinpoint Test H: Transfer Case Actuator Position Sensor Signal B Circuit Tests
- H1: TRANSFER CASE WIRING HARNESS AND ACTUATOR POSITION SENSOR SIGNAL B LOW RESISTANCE
- Set the ignition to off.
- Disconnect the largest wiring harness connector from the transfer case control module.
- Connect an ohm-meter to terminal 6 and terminal 2 of the transfer case control module wiring harness connector.
- Measure the resistance.
Is the measured resistance less than 16 kΩ?
- H2: TRANSFER CASE ACTUATOR POSITION SENSOR SIGNAL B LOW RESISTANCE
- Disconnect the wiring harness connector from the transfer case actuator.
- Connect an ohm-meter to terminal 2 and terminal 7 of the transfer case actuator.
- Measure the resistance.
Is the measured resistance less than 16 kΩ?
- Yes : Resistance too low. Install a new transfer case actuator.
- No : Resistance not too low. Check the transfer case actuator wiring harness for short circuit between the wires. Repair the wiring harness as necessary.
- H3: TRANSFER CASE WIRING HARNESS AND ACTUATOR POSITION SENSOR SIGNAL B HIGH RESISTANCE
- Connect an ohm-meter to terminal 6 and terminal 2 of the transfer case control module wiring harness connector.
- Measure the resistance.
Is the measured resistance greater than 20 kΩ?
- H4: TRANSFER CASE ACTUATOR POSITION SENSOR SIGNAL B HIGH RESISTANCE
- Disconnect the wiring harness connector from the transfer case actuator.
- Connect an ohm-meter to terminal 2 and terminal 7 of the transfer case actuator.
- Measure the resistance.
Is the measured resistance greater than 20 kΩ?
- Yes : Resistance too high. Install a new transfer case actuator.
- No : Resistance not too high. Check the transfer case actuator wiring harness for open circuit, high resistance. Repair the wiring harness as necessary.
- H5: TRANSFER CASE WIRING HARNESS AND ACTUATOR POSITION SENSOR SIGNAL B SHORT CIRCUIT TO GROUND
- Connect an ohm-meter to terminal 6 of the transfer case control module wiring harness connector and ground.
- Measure the resistance.
Is the measured resistance infinitely high (open circuit)?
- Yes : No short circuit to ground. No fault found.
- No : Short circuit to ground. GO to H6.
- H6: TRANSFER CASE ACTUATOR POSITION SENSOR SIGNAL B SHORT CIRCUIT TO GROUND
- Disconnect the wiring harness connector from the transfer case actuator.
- Connect an ohm-meter to terminal 6 of the transfer case control module wiring harness connector and ground.
- Measure the resistance.
Is the measured resistance infinitely high (open circuit)?
- Yes : Short circuit to ground. Install a new transfer case actuator.
- No : No short circuit to ground. Check the transfer case actuator wiring harness for short circuit to ground. Repair the wiring harness as necessary.