DTC B1538-19: Electrically Deployable Tow Bar Movement Motor - Circuit current above threshold: Action
- Check the security and integrity of the deployable towbar circuit connectors and rectify as required
- Refer to the appropriate system wiring diagrams and check the deployable towbar movement motor circuit for short circuit to ground, short circuit to power. Repair circuit as required, clear DTC and retest
- Refer to the appropriate system wiring diagrams and check the deployable towbar motor harness circuits for short circuits. Repair circuit(s) as required, clear DTC and retest
- If the fault persists, install a new deployable towbar movement motor