DTC B10B0-14: Rear Blower Fan Relay - Circuit short to ground or open: Action
- Refer to the appropriate system wiring diagrams and check the rear climate control blower relay circuit for short circuit to ground, open circuit, high resistance
- If fault persists, check and install a new rear climate control blower relay as required