DTC C105B-19: Actuator Circuit Group B - Circuit current above threshold: Action
- Refer to the appropriate system wiring diagram and check the dynamic response control module power supply circuit fuse. Replace as required, clear the DTCs and retest
- Refer to the appropriate system wiring diagram and check the dynamic response control module power supply circuit, harness and connectors - Circuit reference VBATT - For short circuit to ground, short circuit to power. Repair circuit as required, clear the DTCs and retest
- Refer to the appropriate system wiring diagram and check the dynamic response valve circuits for short circuit to ground, short circuit to power. Repair circuit as required, clear the DTCs and retest
- If the fault persists, install a new dynamic response control module