DTC C1119-09: Hydraulic Pressure - Component Failures: Action
- Check and top up the hydraulic fluid as required
- Check integrity of hydraulic system and rectify any leaks as required. Clear the DTCs and retest
- If the fault persists, install a new dynamic response valve block as required and clear adaptive data. Clear the DTCs and retest
- If the fault persists, check the operation of the front and rear actuators and install new actuator(s) as required. Clear the DTCs and retest
- If the fault persists, check the dynamic response hydraulic pump pressure/fluid flow. If faulty, install a new dynamic response hydraulic pump as required