DTC B11A1-11: Right Side Restraints Pressure Sensor - Circuit short to ground: Action
NOTE:
Do not apply compressed air to the component during fault diagnosis. Failure to follow this instruction may result in damage to the component.
- Refer to the appropriate SYSTEM WIRING DIAGRAMS and check the right impact pressure sensor circuit for short circuit to ground. Repair the wiring harness or install a new right impact pressure sensor as necessary