DTC P0715-64: Turbine/Input Shaft Speed Sensor A Circuit - Signal plausibility failure: Action
- Using JLR approved diagnostic equipment, clear the DTCs and retest. Check datalogger signals - Turbine Speed (0x1E72) - Transmission Output Shaft Speed (0x1E68) - for plausibility. If the fault persists, install a new transmission control module. Using JLR approved diagnostic equipment, perform routine - Learn VIN (0x0404) - and - Reset Adaption Values (0x4013) -