DTC B149A-13: Blower Motor - Circuit open: Action
- Refer to the electrical circuit diagrams and check the front blower power and ground circuits for open circuit, high resistance. Repair the wiring harness as necessary
- Using the Jaguar Land Rover approved diagnostic equipment, clear the Diagnostic Trouble Code(s) and retest. If the fault persists, install a new front blower