B1557-2B: Pyrotechnic Brake Pedal Deployment Control - Signal cross coupled: Action
NOTE:
The deployable device connector has a locking plunger (orange tab) which should only fully lock when the two connectors are securely mated, male to female. If the plunger can move to the locked position easily when not mated (for example using reasonable pressure), then this indicates that the connector is damaged. Repair the wiring harness as necessary
- Disconnect the deployable brake pedal connector and apply light pressure to the connector plunger. If the plunger moves to the engaged position the connector is damaged. Repair the wiring harness as necessary
- Refer to the electrical circuit diagrams and check the deployable brake pedal circuit for short circuit to another restraints circuit. Repair the wiring harness as necessary, clear the DTCs and retest