DTC B1211-12: Driver Seatbelt Retractor Pretensioner Deployment Control - Circuit short to battery: Action
NOTE:
When the airbag connector is DISCONNECTED if the locking plunger can move to the locked position easily (reasonable pressure) the connector is damaged
- Visually inspect the driver seatbelt retractor and pretensioner connector, the locking plunger should be flush with the housing. If not, push the locking plunger in. Clear the Diagnostic Trouble Code(s) and retest
- If problem still persists, disconnect and reconnect all connectors. Also test connectors (see above note). Clear the Diagnostic Trouble Code(s) and retest
- Refer to the electrical circuit diagrams and check the driver seatbelt retractor and pretensioner circuit for short circuit to power
- If a wiring fault is detected, repair the wiring as required. Clear the Diagnostic Trouble Code(s) and retest