DTC C1003-77: Right Power Side Step Stow - Commanded position not reachable: Action
NOTE:
- When repairing, disconnect the deployable side step motor electrical connector because of trap hazard near hinges due to unexpected operation
- The physical obstruction might have been removed
- Check the right deployable side step hinges for dirt and debris, wash the step if necessary
- Remove the right deployable side step from hinges. Check the rear hinge for free movement. If movement is restricted renew the right deployable side step rear hinge. Connect the right deployable side step motor electrical connector and check that the front hinge extends when the door is opened. Replace the right deployable side step motor/front hinge assembly as necessary. Clear the Diagnostic Trouble Code(s) and retest