DTC U2006-49: Network Controller - Internal electronic failure: Action
NOTE:
The FlexRay wiring harness must not be repaired by making a localised wiring repair. A new wiring harness should be installed.
- Refer to the appropriate system wiring diagrams and check the powertrain control module power and ground circuits for open circuit, high resistance. Repair the wiring harness as necessary
- Refer to the appropriate system wiring diagrams and check the FlexRay bus circuit for short circuit to ground, short circuit to power, open circuit, high resistance. Repair the wiring harness as necessary