DTC P0616-11 Starter Relay "A" Circuit Low - Circuit short to ground: Action
WARNING: This page is about a different variant/trim than selected.
- Vehicle Conditions to Enable DTC Setting Strategy
- Monitor runs when ignition switched ON
- Prioritized Checks to Perform
- Refer to the appropriate system wiring diagrams and check the starter motor relay circuit for short circuit to ground, high resistance. Check the electrical connectors for evidence of water ingress. Check the terminals for damage and corrosion. Repair the wiring harness as necessary