Temperature Control Lever
Connect ohmmeter between terminals No. 1 and 9 of A/C control assembly 18-pin connector. See Figure. With lever in Max Cool position, resistance should be infinity. With lever in middle position, resistance should be approximately 1500 ohms. With lever in Max Warm position, resistance should be zero ohm. If resistance values are not as specified, replace A/C control assembly.