LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Lexus >> 2006 >> LX 470 >> Repair and Diagnosis >> General Information >> OEM General Information >> Service Specifications >> 2UZ-FE Cooling System >> Service Data
July 1: So it begins. Don't worry, this is not in the correct legal jurisdiction!

Service Data

Water inlet housing with thermostat 

WATER INLET HOUSING WITH THERMOSTAT SERVICE DATA

Condition Specified Condition
Valve opening temperature 80 to 84°C (176 to 183°F)
Valve lift 10 mm (0.39 in.) or more at 95°C 203°F)

Radiator cap 

RADIATOR CAP SERVICE DATA

Item Specified Condition
Standard value (for brand-new cap) 93 to 123 kPa (0.95 to 1.25 kgf*cm2 , 13.5 to 17.8 psi)
Minimum standard value (after using cap) 78 kPa (0.8 kgf*cm2 , 11.4 psi)