Freeze Frame Data
- FREEZE FRAME DATA
- Turn the engine switch off.
- Connect the Techstream to the DLC3.
- Turn the engine switch on (IG).
- Turn the Techstream on.
- Check the freeze frame data. Enter the following menus: Chassis / Tilt & Telescopic / Utility / Freeze Frame Data.
Tilt & Telescopic
NORMAL CONDITION CHARTTester Display Measurement Item/Range Normal Condition Diagnostic Note Tilt Position Current tilt position data / min.: 0, max.: 65535 7000 to 9000 H (28672 to 36864 edge) - Telesco Position Current telescopic position data / min.: 0, max.: 65535 7000 to 9000 H (28672 to 36864 edge) - Up Switch Input state of tilt up by manual switch / ON or OFF ON: Tilt up is activated by manual switch
OFF: Tilt up is not activated by manual switch- Tilt Up SW (MPX) Communication state of tilt up input by manual switch / ON or OFF ON: Tilt up is activated by manual switch
OFF: Tilt up is not activated by manual switch- Down Switch Input state of tilt down by manual switch / ON or OFF ON: Tilt down is activated by manual switch
OFF: Tilt down is not activated by manual switch- Tilt Down SW (MPX) Communication state of tilt down input by manual switch / ON or OFF ON: Tilt down is activated by manual switch
OFF: Tilt down is not activated by manual switch- Telesco Short Switch Input state of telescopic short by manual switch / ON or OFF ON: Telescopic short is activated by manual switch
OFF: Telescopic short is not activated by manual switch- Telesco Short SW (MPX) Communication state of telescopic short input by manual switch / ON or OFF ON: Telescopic short is activated by manual switch
OFF: Telescopic short is not activated by manual switch- Telesco Long Switch Input state of telescopic long by manual switch / ON or OFF ON: telescopic long is activated by manual switch
OFF: Telescopic long is not activated by manual switch- Telesco Long SW (MPX) Communication state of telescopic long input by manual switch / ON or OFF ON: Telescopic long is activated by manual switch
OFF: Telescopic long is not activated by manual switch- T & T Manual SW Data Voltage data of manual switch / min.: 0 V, max.: 5 V Neutral position: Below 0.2 V
Tilt up: 1.67 to 2.13 V
Tilt down: 0.54 to 0.74 V
Telescopic contract: 1.08 to 1.40 V
Telescopic extend: 2.22 to 2.77 V- Power Source Voltage Voltage data of power supply / min.: 0 V, max.: 20 V Actual power supply voltage 10 to 14 V - Freeze Speed Info Vehicle speed data / 0 km/h (0 mph), max.: 255 km/h (158 mph) Actual vehicle speed - IG Switch (MPX) Communication state of engine switch / ON or OFF ON: Communication is normal
OFF: Communication is interrupted- IG Switch Input state of engine switch / ON or OFF ON: Input signal is normal
OFF: Input signal is interrupted- Key Switch/MPX Communication state of key switch confirmation signal / ON or OFF ON: Communication is normal
OFF: Communication is interrupted- Key Code Confirm (MPX) Communication state of key code confirmation signal / ON or OFF ON: Communication is normal
OFF: Communication is interrupted- Receive from Meter Communication state of combination meter signal / OK or Interpt OK: Communication is normal
Interpt: Communication is interrupted- Receive from Body Communication state of body ECU signal / OK or Interpt OK: Communication is normal
Interpt: Communication is interrupted- Receive from Seat ECU Communication state of seat ECU signal / OK or Interpt OK: Communication is normal
Interpt: Communication is interrupted- Receive from Combi Communication state of combination switch ECU signal / OK or Interpt OK: Communication is normal
Interpt: Communication is interrupted- Power ECU Info Communication state of power source control ECU signal / OK or Interpt OK: Communication is normal
Interpt: Communication is interrupted-