Home >> Lexus >> 2008 >> LS 600hL >> Repair and Diagnosis (Single Page) >> Engine Performance >> Engine Control Systems >> Engine Control System - DTC P0010 - P0116 >> DTC P0097: Intake Air Temperature Sensor 2 Circuit Low; DTC P0098: Intake Air Temperature Sensor 2 Circuit High; DTC P0112: Intake Air Temperature Circuit Low Input; DTC P0113: Intake Air Temperature Circuit High Input >> Description
April 5, 2026: LEMON Manuals is launched! Read the announcement.

DTC P0097: Intake Air Temperature Sensor 2 Circuit Low; DTC P0098: Intake Air Temperature Sensor 2 Circuit High; DTC P0112: Intake Air Temperature Circuit Low Input; DTC P0113: Intake Air Temperature Circuit High Input: Description

Fig 1: Intake Air Temperature Sensor Graph
G04942690Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002

The Intake Air Temperature (IAT) sensor, mounted on the Mass Air Flow (MAF) meter, monitors the IAT The IAT sensor has a built-in thermistor with a resistance that varies according to the temperature of the intake air. When the IAT is low, the resistance of the thermistor increases When the temperature is high, the resistance drops These variations in resistance are transmitted to the ECM as voltage changes (See Fig 1).

The IAT sensor is powered by a 5 V supply from the THA and THA2 terminals of the ECM, via resistor R Resistor R and the IAT sensor are connected in series. When the resistance value of the IAT sensor changes, according to changes in the IAT, the voltage at terminal THA and THA2 also varies. Based on this signal, the ECM increases the fuel injection volume when the engine is cold to improve drivability

HINT.

When DTC P0097, P0098, P0112 or P0113 is set, the ECM enters fail-safe mode. During fail-safe mode, the IAT is estimated to be 20°C (68°F) by the ECM Fail-safe mode continues until a pass condition is detected.

DTC DETECTION CONDITION CHART

DTC No. DTC Detection Condition Trouble Area
P0097 Short in Intake Air Temperature (IAT) sensor (for Bank 2) circuit for 0 5 seconds (1 trip detection logic)
  • Short in IAT sensor (for Bank 2) circuit
  • IAT sensor (for Bank 2) (built into MAF meter [for Bank 2])
  • ECM
P0098 Open in Intake Air Temperature (IAT) sensor (for Bank 2) circuit for 0 5 seconds (1 trip detection logic)
  • Open in IAT sensor (for Bank 2) circuit
  • IAT sensor (for Bank 2) (built into MAF meter [for Bank 2])
  • ECM
P0112 Short in Intake Air Temperature (IAT) sensor (for Bank 1) circuit for 0 5 seconds (1 trip detection logic)
  • Short in IAT sensor (for Bank 1) circuit
  • IAT sensor (for Bank 1) (built into MAF meter [for Bank 1])
  • ECM
P0113 Open in Intake Air Temperature (IAT) sensor (for Bank 1) circuit for 0 5 seconds (1 trip detection logic)
  • Open in IAT sensor (for Bank 1) circuit
  • IAT sensor (for Bank 1) (built into MAF meter [for Bank 1])
  • ECM

HINT.

When any of these DTCs are set, check the IAT by entering the following menus.

MALFUNCTION REFERENCE

Temperature Displayed Malfunction
-40°C (-40°F) Open circuit
140°C (284°F) or higher Short circuit