DTC B1795: Occupant Classification ECU Malfunction: Procedure
- CHECK DTC
- Turn the ignition switch to the ON position, and wait for at least 10 seconds.
- Check for DTCs. Refer to DTC CHECK / CLEAR
.
Result
A
DTCs B1771 and B1795 are output.
B
DTC B1795 is output.
HINT:
Codes other than DTCs B1771 and B1795 may be output at this time, but they are not related to this check.
A → GO TO DTC B1771
B: Go to next step
- CHECK FUSE
- Measure the resistance of the ECU-B fuse.
Standard resistance
Below 1 Ω
NG → REPLACE FUSE
OK: Go to next step
- Measure the resistance of the ECU-B fuse.
- CHECK WIRE HARNESS (SOURCE VOLTAGE)
- Turn the ignition switch to the LOCK position.
- Disconnect the negative (-) terminal cable from the battery, and wait for at least 90 seconds.
- Disconnect the connector from the occupant classification ECU.
- Connect the negative (-) terminal cable to the battery.
- Turn the ignition switch to the ON position.
- Measure the voltage according to the value(s) in the table below.
Standard voltage
Tester Connection Condition Specified Condition O3-1 (+B) -
Body groundAlways 10 to 14 V O3-7 (IG) -
Body groundIgnition switch ON 10 to 14 V - Turn the ignition switch to the LOCK position.
- Measure the resistance according to the value(s) in the table below.
Standard resistance
Tester Connection Condition Specified Condition O3-3 (GND) -
Body groundAlways Below 1 Ω
NG → REPAIR OR REPLACE WIRE HARNESS
OK: Go to next step
- REPLACE OCCUPANT CLASSIFICATION ECU
- Turn the ignition switch to the LOCK position.
- Disconnect the negative (-) terminal cable from the battery, and wait for at least 90 seconds.
- Replace the occupant classification ECU. Refer to REMOVAL .
NEXT: Go to next step
- PERFORM ZERO POINT CALIBRATION
- Connect the negative (-) terminal cable to the battery.
- Connect the Techstream to the DLC3.
- Turn the ignition switch to the ON position.
- Using the Techstream, perform "zero point calibration". Refer to INITIALIZATION
.
OK
"Zero Point Calibration is complete" is displayed.
NEXT: Go to next step
- PERFORM SENSITIVITY CHECK
- Using the Techstream, perform "sensitivity check". Refer to INITIALIZATION
.
Standard values
27 to 33 kg (59.52 to 72.75 lb)
NEXT → END
- Using the Techstream, perform "sensitivity check". Refer to INITIALIZATION
.