LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Lexus >> 2010 >> GS 350 AWD >> Repair and Diagnosis (Single Page) >> Electrical >> Starter >> Smart Access System (Keyless Start) (Diagnostic Codes & Symptom Tests) >> Smart Access System With Push-Button Start >> Power Source Mode does not Change >> Procedure
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Power Source Mode does not Change: Procedure

  1. CHECK FOR DTC 
    1. Delete the DTCs.

      HINT: 

      After all DTCs are cleared, check if the trouble occurs again 5 seconds after the engine switch is turned on (IG).

    2. Check for DTCs again.

      OK

      No DTC is output.

    NG → GO TO  DIAGNOSTIC TROUBLE CODE CHART 

    OK: Go to next step 

  2. CHECK BASIC FUNCTION 
    1. When the key is inside the vehicle and the shift lever position is in P, check that depressing the brake pedal causes the engine switch indicator to illuminate green.

      Result

      Result Proceed to
      Indicator illuminates green A
      Engine switch indicator circuit is normal but indicator does not illuminate green B
      Room oscillator recognizes key but indicator does not illuminate green C

    C → GO TO  Engine Switch Indicator Circuit  

    B → GO TO  Room Oscillator does not Recognize Key 

    A → REPLACE POWER SOURCE CONTROL ECU